• Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter
  • Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter
  • Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter
  • Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter
  • Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter
  • Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter

Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter

Customized: Customized
Certification: CE
Display Type: LED
Size: 96*96
Transport Package: 1PCS/Box
Specification: ISO 9001: 2008 Others
Customization:
Gold Member Since 2006

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XMTA-908T
Trademark
CJ
Origin
China
HS Code
9032900090
Production Capacity
100000PCS/Year

Product Description

Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter
Product Description
Specifications

Temperature controller
PID
intelligence dual row 4-LED displays
displaying the measured value and set value.


Main technical specification

1. Measurement deviation: ≤ ± 0.5%F. S± 1B

2. Cold end compensating deviation: ≤ ± 2.0C

3. Sampling cycle: 0.5S

4. Control cycle: Relay output  2-120S, other is 2S.

5. Relay output contact capacity: AC220V/5A (resistance load) or AC220V/0.3A

(perceptual
Load)

6. Driving controllable pulse output: ≥ 3V scope, ≥ 40us width's over zero or trigger contact
pulse

7. Driving solid relay signal output: Driving electric current≥ 15mA, voltage≥ 9V.

8. Continuous PID: 0-10mA (load 500± 200Ω ), 4-20mA (load 250± 100Ω ), or 0-5V

(load≥ 100kΩ ), 1-5V (load≥ 100kΩ )

9. Exterior and hole size(mm): 96× 96× 110 92× 92

10. Power: AC85V242V, 50/60Hz

11. Working condition: Temperature 0-50.0C, relative humidity≤ 85%RH, without corrode

and strong electric radiation.

Panel instruction(consult)
Connection scheme(consult)
 Model code
 
 
                                       XMT (     ) - 9 (    )  8  (    )
                                                          1          2     3      4        5
 
1:The surface dimension (mm)
Blank: 160×80×85 Installation hole 156×76 A: 96×96×80 Installation hole 92×92
D: 72×72×80 Installation hole 68×68 E: 48×96×75 Installation hole 44×92
F: 96×48×75 Installation hole 92×44 G: 48×48×110 Installation hole 44×44
S: 80×160×85 Installation hole 76×156
 
2: Operation display method:'9' 4-key gentle push-switch setting,double row 4-LED digital display,PID and ON/OFF(P=0)control can select.
 
3:Additional alarm:'1' No over-temperature alarm, but a group of time control output;
'3' A group of alarm ( upper limit alarm or follow-up alarm ) and a group of time-control relay output;
'5' No over-temperature alarm, but a group of time control output for buzzer alarm .
 
4:Input: '8' input signal can interchange free(no voltage and current input)
 
5:Suffix Blank:relay output G:solid relay output T:Time control function

Inner parameter
 
Series Code Name Setting range Manual  Ex-Factory
0 SP Setting value of temperature Determined by P-SL P-SH Output corresponds to "OUT" indicator light 50.0
1 AL1 Alarm 1 Determined by P-SL,P-SH when the upper and lower limit alarm, it is0~50.0 when the positive deviation alarm and negative deviation alarm  
please refer to ALP1
Corresponds to "ALM1" indicator light
300
2 AL2 Alarm 2 please refer to ALP2
Corresponds to "ALM2" indicator light
100
3 P Proportion modulus 0~100 When the P↑, the proportion and differential
function↓; If the P↓, the proportion and
differential function↑
When P=0, the meter is ON/OFF control
15
4 I Calculus time 0~2000S   240
5 d Differential time 0~200S   30
6 At Setting itself ON/OFF ON: open setting itself function
OFF: close setting itself function
OFF
7 t Control period 1~120S The movements cycle ON/OFF of Setting relays control is no meaning,
Relay is 20S,  other is 2S.
20
8 Hy Main control by
drop in level
0.1~50.0 Only have meaning when main control output is ON/OFF(P=0) 1.0
9 Hy-1 drop in level
 of  AL1
0.1~50.0 It is used as setting of drop in level
for AL1 relay output  
1.0
10 Hy-2 drop in level
of  AL2
0.1~50.0 It is used as setting of drop in level
for AL2 relay output 
1.0
11 Pb Sensor error amendment ±20.0 The sensor have deviation can use item to revisal 0
12 FILT Filt modulus 0~50 Is the software filter constants of  measurement sampling. The constant ↑, the measurements antijamming capability↑, but the measurement and system time ↓. 20
13 dp Display precision 0~1 1: have radix point; 0: have not radix point 0
14 P-SH The max.value of temperature range - They are used to reset proper temperature range as per user'application.
As for the Max. temperature range for
different inputs, please refer to Sn,
P-SH≥P-SL
1300
15 P-SL The min.value of temperature range - 0
16 OUTL The min. value
of allowable output  
0~OUTH Can achieve low and high output limiter. Meaningless when manual and ON/OFF control 0
17 OUTH The max. value
of allowable output
OUTL~200 200
18 ALP1 Alarm1  and output definition 0~4 'o':indicate no alarm;  '1':upper limit alarm
'2':lower limit alarm;
'3': Upper-limit (deviation) Alarm;
'4': Lower-limit (deviation) Alarm;
-
19 ALP2 Alarm2  and output definition 0~4 -
20 COOL System function choice 0~1 '0': reverse control(heat)
'1': positive control(cool)
0
21 OPPO Open power output 0~100 Soft start functionthat meters coefficient after first export of electric power 0
22 LOCK Code lock 0~50 LOCK=0, all the parameter can be revised
LOCK=1, only the SP can be revised
LOCK>1, all the parameter can not be revised
0
23 Sn Input type CU50( )
PT100( )
PT100( )
K( ),E( ),J( )
T( ),S( )
CU50 (-50.0~150.0ºC) ;
PT1 (-200.0~200.0ºC) ;
PT2 (-200.0~600.0ºC) ;K (0~1300ºC) ;
E (0~700.0ºC) ;      J (0~900.0ºC) ;
T (-200~400.0ºC) ;   S (0~1600ºC) ;
 
24 OP-A Output type  
RLP( )
SSR( )
Zero( )
Mut( )
0~10MA( )
4~20MA( )
RLP Relay output mode
SSR Solid state relay
Zero   SCR zero voltage switching
Mut   SCR phase-shift trigger
0~10MA linearity  control electric current output
4~20MA  linearity  control electric current output
 
__
 
 
 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now