• Yuyao Gongyi Meter Co., Ltd. Cj Xmtd-Jk208 2 Channlel Intelligent Pid Temperature Controller
  • Yuyao Gongyi Meter Co., Ltd. Cj Xmtd-Jk208 2 Channlel Intelligent Pid Temperature Controller
  • Yuyao Gongyi Meter Co., Ltd. Cj Xmtd-Jk208 2 Channlel Intelligent Pid Temperature Controller

Yuyao Gongyi Meter Co., Ltd. Cj Xmtd-Jk208 2 Channlel Intelligent Pid Temperature Controller

Customized: Customized
Certification: RoHS, CE, ISO
Display Type: LED
Size: 72*72
Control Type: Digital
Type: Temperature Controller
Customization:

Contact Supplier

Gold Member Since 2006

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XMTD-JK208
Control Method
Electronic Type
Usage
Temperature Control
Transport Package
1PCS/Box
Specification
ISO 9001: 2008 Others
Trademark
CJ
Origin
China
HS Code
9032900090
Production Capacity
100000PCS/Year

Product Description

I.Summary
XMT*JK four-way temperature controller can connect four sensors synchronously and conveniently, diminish the instrument's volume. It has a separate auto-tune mode and PID parameter function with more precision and more reliability in whole machine control.

II.Primary technical standard
1, Input signal: CU50(-50.0~150.0C), Pt100(-19.9~600.0C), K(0~1300C),
E(0~700.0C), J(0~900.0C)
2, Accuracy: ± 0.5%F. S± 1byte
3, Output method: Relay AC220V 3A(resistance load)
4, control mode: Difference control-on/off and PID control
5, Input power: AC85~242V 50/60Hz
6, Environment Temperature: 0 to 50C, Humidity: ≤ 85%RH
7, Face Size: 160× 80× 110 mm Hole Size: 152× 76 mm
96× 96× 110 mm Hole Size: 92× 92 mm
72× 72× 110 mm Hole Size: 68× 68 mm

Pannel Instruction
Yuyao Gongyi Meter Co., Ltd. Cj Xmtd-Jk208 2 Channlel Intelligent Pid Temperature Controller

Connection Method
Yuyao Gongyi Meter Co., Ltd. Cj Xmtd-Jk208 2 Channlel Intelligent Pid Temperature Controller




Code setting mode
Series Code Name Setting range Manual Remarks



First










Menu
0 LOCK Code lock 0~50 18-all the parameter can be revised,
 
18
1 Sn Input type   -- CU50,Pt100,K,E,J K

2

ALP

Alarm define

0~6
0:no alarm,1:upper limit alarm,2:low limit alarm,3:upper windage alarm,
4 :lower windage alarm 5:between besides alarm,6:between inside alarm

1
3 t Output cycle 0~120 S relay control action cycle setting 10 S
4 dp display accuracy 0~1 0. no decimal;   1.have decimal 0
5 P-SH Upper limit P-SL~full range this parameter resreict enactment value's
upper
according request
6 P-SL lower limit Range jumping-off ~P-SH this parameter resreict enactment
value's low
according request
7 OPB Assistant output method 0~2
no  Assistant output;
1.RS485 communication
2.Mini pinter
0
8 Add address 1~64
(1~9999)
Meter's NO
(in minitype as print times)
1
9 bt baud rate 0~3 0:1200; 1:2400;
3:4800; 4:9600
9600

 



Second







Menu
10 SP+N(1~2) N channels control setting Range by P-SL,P-SH decide Control value setting default
 
11 AL+N Alarm  value setting Range by P-SL,P-SH decide Output mode decide by 'AL-P' default
12 SC+N Sensor error amendment ±20.0 The sensor have deviation can use
item to revisal
0.0
13 P+N Proportion modulus 0~100 When P↑, proportion function↓, clash↓, but too big will add the heating time
When P=0, the instrument is ON/OFF control.
15.0



14



I+N



Calculus time


0~3000
Set integral time so as to unchain residual deflection caused by proportion control. To increase it, the static  difference will be reduced, but when it is too high ,thestatic difference will drift
instability.


240

15

d+N
differential time
0~200S
Set differential time to avoid fluctuation of
output so as to improve the steady of
control.

30
16 Hy+N Main control by drop in level 0.1~50.0 It only controls at ON/OFF 1.0
17 At+N Setting itself 0~1 0:close setting itself function
1:open setting itself function
0



 