• Four-Way Temperature Controller (XMT-JK408)
  • Four-Way Temperature Controller (XMT-JK408)
  • Four-Way Temperature Controller (XMT-JK408)
  • Four-Way Temperature Controller (XMT-JK408)

Four-Way Temperature Controller (XMT-JK408)

Customized: Customized
Certification: RoHS, UL, CE, ISO
Display Type: LED
Size: 160*80
Type: Temperature Controller
Control Type: Digital
Customization:
Gold Member Since 2006

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XMT-JK408
Control Method
Electronic Type
Usage
Temperature Control
Transport Package
1PCS/Box
Specification
ISO 9001: 2008 Others
Trademark
CJ
Origin
China
HS Code
9032900090
Production Capacity
100000PCS/Year

Product Description

I.Summary
XMT*JK four-way temperature controller can connect four sensors synchronously and conveniently, diminish the instrument's volume. It has a separate auto-tune mode and PID parameter function with more precision and more reliability in whole machine control.

II.Primary technical standard
1, Input signal: CU50(-50.0~150.0C), Pt100(-19.9~600.0C), K(0~1300C),
E(0~700.0C), J(0~900.0C)
2, Accuracy: ± 0.5%F. S± 1byte
3, Output method: Relay AC220V 3A(resistance load)
4, control mode: Difference control-on/off and PID control
5, Input power: AC85~242V 50/60Hz
6, Environment Temperature: 0 to 50C, Humidity: ≤ 85%RH
7, Face Size: 160× 80× 110 mm Hole Size: 152× 76 mm
96× 96× 110 mm Hole Size: 92× 92 mm
72× 72× 110 mm Hole Size: 68× 68 mm

Panel board instruction(consult)



Four-Way Temperature Controller (XMT-JK408)
Connection scheme(consult)


Four-Way Temperature Controller (XMT-JK408)


 
Series Code Name Setting range Manual Remarks
 
 
 
First
 
 
 
 
 
 
Menu
0 LOCK Code lock 0~50 LOCK=18,all the parameter can be revised 18

 
1 Sn Input type 0~4 CU50\Pt100\K\E\J K

 
 
 
2*
 
 
ALP
 
 
Alarm define 
 
 
0~6
0:no alarm\1:upper limit alarm\2:low limit alarm\3:upper warp alarm\4:low warp alarm\
5:between besides alarm\
6:between inside alarm
 
 
1

 
3 t Output cycle 0~120 S relay control action cycle setting 10 S

 
4 dp display accuracy 0~1 1: have radix point,
0: have not radix point
0

 
5 P-SH Upper limit P-SL~full range this parameter resreict enactment
value's upper  
according request 

 
 
6
 
P-SL
 
lower limit
Range jumping-off ~P-SH this parameter resreict enactment
value's low
according request

 
 
7
 
OPB
Assistant output method  
0~2
0:no  Assistant output;
1:RS485 communication
2:Mini pinter
 
0

 
8 Add address 1~64
(1~9999)
Meter's NO
(in minitype as print times)
1

 
9 bt baud rate   __ 0:1200; 1:2400;
3:4800; 4:9600
9600
9600

 
 
 
 
Second
 
 
 
 
 
 
 
Menu  
 
10
SP+N(1~4) N channels control setting Range by P-SL\P-SH decide  
Control value setting
 
default
 

 
 
11
 
AL+N
Alarm  value setting Range by P-SL\P-SH decide  
Output mode decide by 'AL-P' 
 
default

 
12 SC+N Sensor error amendment ±20.0 The sensor have deviation 
can use item to revisal
0

 
 
13
 
P+N
 
Proportion modulus
 
0~100
When the P increase, the proportion function decrease.
When P=0,the meter 
is ON/OFF control
 
8

 
 
 
 
14
 
 
 
I+N
 
 
 
Integral time
 
 
 
0~3000
Set integral time so as to unchain residual. Deflection caused by proportion control. To increase it, the static difference will be reduced, but when it is too high ,the static difference will drift instability.  
 
 
240

 
 
15
 
d+N
 
differential time
 
0~200S
Set the differential time,so as to avoid. The output's fluctuation,Improve the control's stability.  
30

 
 
16
 
Hy+N
Main control by
drop in level
 
0.1~50.0
 
-
 
1.0

 
17* At+N Setting itself 0~1 0:close setting itself function   1:open setting inself function 0

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now