Programmable Temperature Controller (XMT-908P)

Customized: Customized
Certification: CE
Brand: Cj
Display Type: LED
Model: Xmt-908p
Size: 160*80mm
Customization:
Gold Member Since 2006

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XMT-908P
Transport Package
1PCS/Box
Specification
ISO 9001: 2008Others
Trademark
CJ
Origin
China
HS Code
9032900090
Production Capacity
100000PCS/Year

Product Description

I.Main Technical Indexes
1   Basic error≤±0.5%F.S±1,±0.3%F.S±1

2   Cold end compensating deviation:  ≤±2.0ºC

3   Sampling period:0.5 second

4   Control cycle:relay output 2~120S , other is 2S.

5   Alarm output the drop in level:  0.5 or 5

6    Relay output contact capacity:AC250V/7A (resistance load) or AC250V/0.3A (perceptual load)

7   Dring controllable pulse output:≥3V scope,≥50μS widthcontact with pulse when move to exceed zero

8   Driving solid relay signal output: driving electric current≥15mA, voltage≥9V.

9   Continuous PID  : 0~10mA (load 500±200Ω), 4~20mA (load 250±100Ω),       
or 0~5V (load≥100kΩ) , 1~5V (load≥100kΩ)

10  Power: AC90V~242V, 50/60Hz

11  Work environmenttemperature 0~50.0ºC, relative humidity≤85RH, without corrode and strong electric radiation.


II.Operation method of running curve program
1. Three work state of the meter

State of stop:
When the meter is in the state of stop, the meter is used as the thermostatic control, the setting value is
the basic setting value(SP), display in the window below, the running indicator light turn off.

State of running:
When the meter is in the state of running, the meter constantly modify the setting value (SV)according to the setting curve, make the measured value(PV) changing according to the curve program, so as to achieve the purpose of curve program control, and the indicator light turn bright.

State of interim:
When the meter is in the state of interim, the calculagraph stop timing, the setting value(SV)maintain unchanged, and it also will prolong the running time of the curve program, the indicator light will coruscate.

State of automatic pause:
The state of automatic pause is the special form of the state of interim, created by the meter itself, not can be controlled by artifial. In the running state, when the deviation absolutevalue of themeasured value and present setting value(SV)>automatic pause strap (AL_P), the meter enter into the pause state, the indicator light will coruscate., the calculagraph stop timing, the setting value(SV)will not change. When the deviation absolutevalue of themeasured value and present setting value(SV)< automatic pause strap (AL_P), the meter will automatically resume the running state.

Hold state:
When the meter finish the curve program, and some section r=0, the meter will enter into the hold state (run=1), and the main control output closed, the indicator light turn off, the below window display the first setting value. When the outer switch touch off or set the meter Run parameter to 3, it can restart.

2. Disposal on the power-cut
During the running process of the curve program, the meter will for every 5 minutes to save the running parameter and the running state data, so when the power is off and then on, the meter only run according to the last saved data to continue,
Not from the beginning(if it need to start from beginning, press reposition key to start.

Product code:

Programmable Temperature Controller (XMT-908P)
 Connection(consult)   
 Note:Only one way for alarm use Alarm 1.only when alarm method ALP is (upper and lower limit alarm),

6(upper and lower deviation alarm) 
,

(upper and upper limit alarm) ,10 (lower and lower limit alarm),it should use 

Alarm 2,when upper and lower limit alarm or upper and lower deviation alarm,it should use Alarm 2 as lower limit or lower 

deviation alarm.The indicator light will be lighten when the alarm output.
 

Note : when input current signal 0-10mAor 4-20mA ,it should respectively combine 1K or 250 250Ω
 to input port.Change the current signal to voltage signal. 