• Cj Intelligent Temperature Controller Withalarm Control (XMT-918)
  • Cj Intelligent Temperature Controller Withalarm Control (XMT-918)
  • Cj Intelligent Temperature Controller Withalarm Control (XMT-918)
  • Cj Intelligent Temperature Controller Withalarm Control (XMT-918)
  • Cj Intelligent Temperature Controller Withalarm Control (XMT-918)
  • Cj Intelligent Temperature Controller Withalarm Control (XMT-918)

Cj Intelligent Temperature Controller Withalarm Control (XMT-918)

Customized: Customized
Certification: CE
Display Type: LED
Size: 160*80
Control Type: Digital
Type: Temperature Controller
Customization:
Gold Member Since 2006

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XMT-918
Control Method
Electronic Type
Usage
Temperature Control
Transport Package
1PCS/Box
Specification
ISO 9001: 2008Others
Trademark
CJ
Origin
China
HS Code
9032900090
Production Capacity
100000PCS/Year

Product Description

Product Description
XMT908 intellectual ability temperature controller
Intelligence industrial regulation instrument
A high performance
Cj Intelligent Temperature Controller Withalarm Control (XMT-918)

XMT-908 intelligence-ability temperature controller is a kind of high performance & reliability intelligence-ability temperature control meter, they are widely used in the automatic control system of the temperature, chemical, ceramics, light, metal, petrochemical and heat treatment industry

Main technical specification
1. Measurement deviation: ≤ ± 0.5%FS± 1.
2. Sampling cycle: 0.5S.
3. Control cycle: Relay output 2~120S, other is 2S...
4. Relay output contact capacity: AC250V/7A (resistance load) or AC250V/0.3A (perceptual load).
5. Driving controllable pulse output: ≥ 3V scope, ≥ 40us width's over zero or trigger contact pulse.
6. Driving solid relay signal output: Driving electric current≥ 15mA, voltage≥ 9V...
7. Continuous PID: 0~10mA (load 500± 200Ω ), 4~20mA (load 250± 100Ω ), or 0~5V (load≥ 100kΩ ), 1~5V (load≥ 100kΩ ).
8. Power supply: AC90V~242V, 50/60Hz.
9. Working condition: Temperature 0~50.0, relative humidity≤ 85%RH, without corrode and strong electric radiation.
10. Exterior and hole size(mm): 160× 80× 120 152× 76;

Panel instruction(consult)
Flow chart

 

Series
Code Name Setting range Manual Ex-Factory
0 SP Setting value of temperature Determined by P-SL P-SH Output corresponds to "OUT" indicator light 50.0
1 AL1 Alarm 1 Determined by P-SL,P-SH when the upper and lower limit alarm, it is0~50.0 when the positive deviation alarm and negative deviation alarm
please refer to ALP1
Corresponds to "ALM1" indicator light
300
2 AL2 Alarm 2
 
please refer to ALP2
Corresponds to "ALM2" indicator light
100
3 P Proportion modulus 0~100 When the P↑, the proportion and differential
function↓; If the P↓, the proportion and
differential function↑
When P=0, the meter is ON/OFF control
15
4 I Calculus time 0~2000S
 
240
5 d Differential time 0~200S
 
30
6 At Setting itself ON/OFF ON: open setting itself function
OFF: close setting itself function
OFF
7 t Control period 1~120S The movements cycle ON/OFF of Setting relays control is no meaning,
Relay is 20S,  other is 2S.
20
8 Hy Main control by
drop in level
0.1~50.0 Only have meaning when main control output is ON/OFF(P=0) 1.0
9 Hy-1 drop in level
of  AL1
0.1~50.0 It is used as setting of drop in level
for AL1 relay output
1.0
10 Hy-2 drop in level
of  AL2
0.1~50.0 It is used as setting of drop in level
for AL2 relay output
1.0
11 Pb Sensor error amendment ±20.0 The sensor have deviation can use item to revisal 0
12 FILT Filt modulus 0~50 Is the software filter constants of  measurement sampling. The constant ↑, the measurements antijamming capability↑, but the measurement and system time ↓. 20
13 dp Display precision 0~1 1: have radix point; 0: have not radix point 0
14 P-SH The max.value of temperature range - They are used to reset proper temperature range as per user'application.
As for the Max. temperature range for
different inputs, please refer to Sn,
P-SH≥P-SL
1300
15 P-SL The min.value of temperature range -
 
0
16 OUTL The min. value
of allowable output
0~OUTH Can achieve low and high output limiter. Meaningless when manual and ON/OFF control 0
17 OUTH The max. value
of allowable output
OUTL~200
 
200
18 ALP1 Alarm1  and output definition 0~4 'o':indicate no alarm;  '1':upper limit alarm
'2':lower limit alarm;
'3': Upper-limit (deviation) Alarm;
'4': Lower-limit (deviation) Alarm;
-
19 ALP2 Alarm2  and output definition 0~4
 
-
20 COOL System function choice 0~1 '0': reverse control(heat)
'1': positive control(cool)
0
21 OPPO Open power output 0~100 Soft start functionthat meters coefficient after first export of electric power 0
22 LOCK Code lock 0~50 LOCK=0, all the parameter can be revised
LOCK=1, only the SP can be revised
LOCK>1, all the parameter can not be revised
0
23 Sn Input type CU50( )
PT100( )
PT100( )
K( )\E( )\J( )
T( )\S( )
CU50 (-50.0~150.0ºC) ;
PT1 (-200.0~200.0ºC) ;
PT2 (-200.0~600.0ºC) ;K (0~1300ºC) ;
E (0~700.0ºC) ;      J (0~900.0ºC) ;
T (-200~400.0ºC) ;   S (0~1600ºC) ;

 
24 OP-A Output type
RLP( )
SSR( )
Zero( )
Mut( )
0~10MA( )
4~20MA( )
RLP Relay output mode
SSR Solid state relay
Zero   SCR zero voltage switching
Mut   SCR phase-shift trigger
0~10MA linearity  control electric current output
4~20MA  linearity  control electric current output

__

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now