I.Product characteristic
The core of the product adopts the up-to-date microprocessor chip.
Red and green double-bank nixie tube display the measured value and setting value.
Easy operation in the four keys, & fast setting in the parameter.
Control in high precision's PID intelligent and two or three bit location check program.
Upper-bank display the measured value, & bottom-bank display the setting value under normal working conditions.
II.Primary technical standard
1. Input: Thermocouple: K\E\J\S; Thermal resistance: PT100 CU50
2. Range: K(0~400\0~1300)\E(0~400\0~800)\J(0~1000) S(0~1600)\PT100(-100.0~200.0\0~600)\CU50(-50.0~150.0)
3. Measure error: ± 0.5%F. S± Byte
4. Silicon control trigger signal(over zero): Range≥ 3V, Width≥ 40us
5. The output contact potential of the relay: Impedance load 7A
6. Input power: AC85~242V 50/60Hz
7. Entironment: Temperature: 0 to 50, Humidity: ≤ 85%RH
8. External dimension: 96× 96× 110 hole 92× 92
Size: XMT:80×160×110mm hole: 76×152; XMTA:96×96×110mm hole: 92×92;
XMTE:48×96×110mm hole: 44×92; XMTF:96×48×110mm hole: 92×45;
XMTD:72×72×110mm hole: 68×68; XMTG:48×48×110mm hole: 45×45;
Name and functions of the sections
(1)PV display
Indicates the process variable (PV) with a red LED.
(2)SV display
Indicates the setting value (SV) with a green LED.
(3)ALM1 indicator
When ALM1 output is ON, a red LED lights.
(4)ALM2 indicator
When ALM2 output is ON, a red LED lights.
(5)AT indicator
When auto tuning function is ON, a green LED lights.
(6)OUT indicator
When OUT is ON, a green LED lights.
(7)Mode key (SET)
Switches the setting mode and registers the setting value and selected value.
(Setting value and selected value are registered by pressing the mode key.)
(8)Data shift key (<)
(9)Decrease key (∨)
Decreases numeric value of the setting value
(10)Increase key (∧)
Increases numeric value of the setting value.
Connection figure(consult)