Specifications
Temperature controller
Intelligence dual row 4-LED diSplay
Operated with 4-key
Control method: On/off, automatic regulation
XMT*7000 series temperature controller are intelligence dual row 4-LED display for displaying the measured value and set value respectively. The temperature meter are operated with 4-keys, allowing an easy inputting. The available control methods include on/off, 2-on/off, PID and automatic regulating and setting controls.
Features:
1) Intelligence dual row 4-LED display for displaying measured values and setting value respectively
2) Operated with 4 keys, allowing easy inputting
3) Control methods available: On/off, 2-on/off, PID and automatic regulating and setting controls
4) Demonstrates superb quality because of special design of their interference-resistance and application of the high interference resistant chips made hy prestigious companies abroad
5) Input signal: Thermocouple and thermresistance
6) Contact capacity: 7A resistance
7) Law or regulation: On/off, automatic regulating PID
8) Power source: AC 90 242V 50Hz/60Hz
9) Accuracy: Class0.5%F. S± 1b
10) Additional cold end compensation deviation: ± 1° C
Dimensions:
1) XMTA:
A) Exterior size: 96 X 96 X 80
B) Installation hole: 92 X 92
2) XMTD:
A) Exterior size: 72 X 72 X 100
B) Installation hole: 68 X 68
3) XMTE:
A) Exterior size: 48 X 96 X 80
B) Installation hole: 44 X 92
4) XMTF:
A) Exterior size: 96 X 48 X 80
B) Installation hole: 92 X 44
5) XMTG:
A) Exterior size: 48 X 48 X 90
B) Installation hole: 45 X 45
6) XMTS:
A) Exterior size: 80 X 160 X 80
B) Installation hole: 76 X 152
7) XMTC:
A) Exterior size: 78 X 54 X 30
B) Installation hole: 78 X 54 X 30
8) XMT:
A) Exterior size: 160 X 80 X 80
B) Installation hole: 152 X 76
Setup flow chart
Code |
Description |
Setting range |
Instruction |
Remarks |
SP |
Setting control point |
Whole range |
ºC or 1 defined unit |
_ |
AL1 |
Alarm 1 |
Whole range |
ºC or 1 defined unit |
|
AL2 |
Alarm 2 |
Whole range |
ºC or 1 defined unit |
|
SC |
Measurement update |
-20.0 to 20.0 |
Measuring value can be modified through increasing or decreasing this data. Note: It may be cause inaccurate racy of measuring value when you use this function . Please use the function carefully according to your situation. |
0 |
P |
Proportional band |
0 to 9999 |
When the P↑,the proportion and differential function↑; if the P↓,the proportion and differential function↓. When P=0,the meter is ON/OFF control |
100 |
I |
Integration time |
0 to 3000s |
It's mainly used to adjust the static difference. To increase it, the static difference will be reduced, but when it is too high, the static difference will drift instability. |
500 |
d |
Differential time |
0 to 2000s |
When the I↓,the calculus function↑; I↑the calculus function↓. When I=0, no calculus function, it is PD adjustment instrument |
100 |
t |
Control period |
1 to 120s |
When the d↓,the proportion and calculus function↑; if d↑,the proportion and calculus function↓,but the differential function↑. When d≤t, it has no differential function |
20 |
Hy |
Deadband |
0.1to 50.0 |
ON/OFF control only |
1.0 |
At |
Auto-man |
0 to 1 |
- Close auto-man function
- Open auto-man function
|
0 |
Lock |
Key lock |
0 to 1 |
- All the parameter can rework
- Only SP value can rework
>1 All the parameter can not rework |
0 |