• Cj Xmta-Jk408 4 Channlel Intelligent Pid Temperature Controller
  • Cj Xmta-Jk408 4 Channlel Intelligent Pid Temperature Controller

Cj Xmta-Jk408 4 Channlel Intelligent Pid Temperature Controller

Customized: Customized
Certification: RoHS, UL, CE, ISO
Display Type: LED
Size: 96*96
Control Type: Digital
Type: Temperature Controller
Customization:
Gold Member Since 2006

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XMTA-JK408
Control Method
Electronic Type
Transport Package
1PCS/Box
Specification
ISO 9001: 2008 Others
Trademark
CJ
Origin
China
HS Code
9032900090
Production Capacity
100000PCS/Year

Product Description

Summary

XMT*JK408 temperature controller can connect four sensors synchronously and conveniently, diminish the

instrument's volume. It has a separate auto-tune mode and PID parameter function with more precision and
more reliability in whole machine control.

Primary technical standard:
1.Input signal: CU50(-50.0~150.0)\PT100(-19.9~600.0)\K(0~1300)\

E(0~700.0)\J(0~900.0)

2.Accuracy: ± 0.5%F. S± 1byte

3.Output method: Relay AC220V 3A(resistance load)

4.control mode: Difference control-on/off and PID control

5.Input power: AC85~242V 50/60Hz

6.Environment Temperature: 0 to 50, Humidity: ≤ 85%RH

7.Overall size and installation hole (mm):
XMTA: 96× 96× 110; 92× 92

Panel board instruction(consult)


Cj Xmta-Jk408 4 Channlel Intelligent Pid Temperature Controller

Connection scheme(consult)

Cj Xmta-Jk408 4 Channlel Intelligent Pid Temperature Controller


Code setting mode

Series
Code Name Setting range Manual Remarks



First






Menu
0 LOCK Code lock 0~50 LOCK=18,all the parameter can be revised 18
1 Sn Input type 0~4 CU50,Pt100,K,E,J K


2*


ALP


Alarm define


0~6
0:no alarm,1:upper limit alarm,2:low limit alarm,3:upper warp alarm,4:low warp alarm,
5:between besides alarm,
6:between inside alarm


1
3 t Output cycle 0~120 S relay control action cycle setting 10 S
4 dp display accuracy 0~1 1: have radix point,
0: have not radix point
0
5 P-SH Upper limit P-SL~full range this parameter resreict enactment
value's upper
according request

6

P-SL

lower limit
Range jumping-off ~P-SH this parameter resreict enactment
value's low
according request

7

OPB
Assistant output method
0~2
0:no  Assistant output;
1:RS485 communication
2:Mini pinter

0
8 Add address 1~64
(1~9999)
Meter's NO
(in minitype as print times)
1
9 bt baud rate   -- 0:1200; 1:2400;
3:4800; 4:9600
9600
9600

 



Second







Menu

10
SP+N(1~4) N channels control setting Range by P-SL,P-SH decide
Control value setting

default
 

11

AL+N
Alarm  value setting Range by P-SL,P-SH decide
Output mode decide by 'AL-P'

default
12 SC+N Sensor error amendment ±20.0 The sensor have deviation
can use item to revisal
0

13

P+N

Proportion modulus

0~100
When the P increase, the proportion function decrease.
When P=0,the meter
is ON/OFF control

8



14



I+N



Integral time



0~3000
Set integral time so as to unchain residual. Deflection caused by proportion control. To increase it, the static difference will be reduced, but when it is too high ,the static difference will drift instability.


240

15

d+N

differential time

0~200S
Set the differential time,so as to avoid. The output's fluctuation,Improve the control's stability.
30

16

Hy+N
Main control by
drop in level

0.1~50.0

-

1.0
17* At+N Setting itself 0~1 0:close setting itself function   1:open setting inself function 0