Product Description
Key Specifications
1. Input and rangeone meter can be compatible
(1) Thermocouple: K (-50~1300oC), S (-50~+1700oC), T (-200~+350oC), E (0~800oC), J ( 0~1000oC), B (0~1800oC), N (0~1300oC), WRe (0~2300oC)
(2) Thermal resistance: CU50 (-50~150oC) PT100 (-20~600oC)
(3) Linearity voltage05V15V01V0100mV020mV
(4) Linearity currentwith diffluent resistance010mA020mA420mA
(5) Linearity input: -1999~+9999 (user freely setting)
2. Precision
(1) Input by thermal resistance, linearity voltage and linearity current 0.5F. S± 1
(2) Thermocouple input adopt copper resistance or freezing compensate cold end 0.5 F. S± 1
(3) Although the meter can measure B, S, WRE during the temperature 0~600oC, its measurement could not reach 0.5 class
(4) differentiate rate1, 0.1
3. Response time
≤ 0.5s (filter parameter sets 0)
4. Adjusting mode
(1) ON/OFF control methodReturn difference can be adjusted
(2) Common PID controlwith the parameter of self-setting function
(3) Intelligence adjustment(including vague PID adjustment and advanced control algorithm with the parameter of self-setting function)
5. Output specificationit make out directly output parameter modularity or without modularity
(1) The switch of relay contact point outputopen+ closed250VAC/7A or 30VDC/10A
(2) SSR voltage: 12VDC/30mA(apply for driving SSR relay)
(3) Contact point output with controllable silicon: Can contact 5~500A two directions controllable silicon; 2 separate directions controllable silicon opposite direction parallel.
(4) Liner electric current output initial current and terminal current value can be defined when the output is 0~24mAvoltage range 11~23VDC
6. Communication
Support RS485communication mode, adopt AIBUS communication agreement, and baud rate support the below selection 1200bps4800bps7200bps9600bps
7. Alarm
Support two passive contact output, relay contact 250VAC/7AIt has four methods including upper limit, lower limit, positive deviation, negative deviation. It can output 2 ways at most
8. Tolerance for pressure when it is segregated
Between electric power, relays contact and signals end, do 2000V pressure tolerance test 1s, there is no abnormal phenomenon;
9. Movement with hand
Automatic /Manual
10. Power supply
(1) 85V-242VAC, 50-60HZpower consumption ≤ 4W
(2) 24VDC/AC power consumption≤ 4W
(3) 220VAC± 10% 50HZpower consumption≤ 4W
11. Working circumstance
Environment temperature: 0~50, humidity ≤ 85, no corrode and strong electromagnetism disturb
12. Product authentication
XMT*-808 series temperature meter acquire CE authentication and ROHS Environmental Protection authentication.
Product code
XMT ___ 8 ___ 8 ____
( 1) (2) (3) (4) (5)
1. The surface dimension
Blank: 160×80×120 Installation hole 152×76
A: 96×96×110 Installation hole 92×92
D:72×72×110 Installation hole 68×68
E: 48×96×110 Installation hole 44×92
F:96×48×110 Installation hole 92×44
S:80×160×120 Installation hole 76×156
G:48×48×110 Installation hole 44×44
2. Control Mode: '8' four key set, two row LED display,,fuzzy control.
3. Additional alarm: '0' no alarm ; '1' one group alarm ; '3' two group alarms; ' 5' voice alarm
4. Signal input type '8' freely exchange signal
5. Suffix
Main control output method
'Blank' : relays open and closed contact output
'A' : Single-phase over-zero spark pulse
'A3' :Three-phase over-zero spark pulse;
BSingle-phase shift-phase spark pulse
'B3' : Three-phase shift-phase spark pulse
'C' : 010mA or 420mA constant electric current output
'E' : Linearity voltage output
'G' : ON/OFF solid state relaySSRadjustment output
Auxiliary ways
'K' : with RS485 or RS232 communication module interface
'Wt': with micro-printer output signal
'V' : DC24VDC12VDC5V output
'P' : 30 segment program