Code | Description | Setting range | Instruction | Remarks |
SP | Setting control point | Whole range | ºC or 1 defined unit | |
AL1 | Alarm 1 | Whole range | ºC or 1 defined unit | |
AL2 | Alarm 2 | Whole range | ºC or 1 defined unit | |
SC | Measurement update | -20.0 to 20.0 | Measuring value can be modified through increasing or decreasing this data. Note: It may be cause inaccurate racy of measuring value when you use this function . Please use the function carefully according to your situation. |
0 |
P | Proportional band | 0 to 9999 | When the P↑,the proportion and differential function↑; if the P↓,the proportion and differential function↓. When P=0,the meter is ON/OFF control | 100 |
I | Integration time | 0 to 3000s | It's mainly used to adjust the static difference. To increase it, the static difference will be reduced, but when it is too high, the static difference will drift instability. | 500 |
d | Differential time | 0 to 2000s | When the I↓,the calculus function↑; I↑the calculus function↓. When I=0, no calculus function, it is PD adjustment instrument |
100 |
t | Control period | 1 to 120s | When the d↓,the proportion and calculus function↑; if d↑,the proportion and calculus function↓,but the differential function↑. When d≤t, it has no differential function |
20 |
Hy | Deadband | 0.1to 50.0 | ON/OFF control only | 1.0 |
At | Auto-man | 0 to 1 | Close auto-man function Open auto-man function |
0 |
Lock | Key lock | 0 to 1 | All the parameter can rework Only SP value can rework >1 All the parameter can not rework |
0 |