• Cj Pid Temperature Controller for Heat Press Machine (XMTD-9000)
  • Cj Pid Temperature Controller for Heat Press Machine (XMTD-9000)
  • Cj Pid Temperature Controller for Heat Press Machine (XMTD-9000)

Cj Pid Temperature Controller for Heat Press Machine (XMTD-9000)

Certification: RoHS, CE, ISO
Display Type: LED
Size: 72*72
Type: Temperature Controller
Control Type: Digital
Control Method: Electronic Type
Customization:

Contact Supplier

Gold Member Since 2006

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XMTD-9000
Usage
Temperature Control
Transport Package
1PCS/Box
Specification
ISO 9001: 2008 Others
Trademark
CJ
Origin
China
HS Code
9032900090
Production Capacity
100000PCS/Year

Product Description

1. Input: Thermocouple: K\E\J\S; Thermal resistance: PT100 CU50
2. Range: K(0~400\0~1300)\E(0~400\0~800)\J(0~1000) S(0~1600)\PT100(-100.0~200.0\0~600)\CU50(-50.0~150.0)
3. Measure error: ± 0.5%F. S± Byte
4. Silicon control trigger signal(over zero): Range≥ 3V, Width≥ 40us
5. The output contact potential of the relay: Impedance load 7A
6. Input power: AC85~242V 50/60Hz
7. Entironment: Temperature: 0 to 50, Humidity: ≤ 85%RH
8. External dimension: 72× 72× 110 hole 68× 68
Cj Pid Temperature Controller for Heat Press Machine (XMTD-9000)
Size: XMT:80×160×110mm  hole: 76×152;  XMTA:96×96×110mm  hole: 92×92;
    XMTE:48×96×110mm   hole: 44×92;  XMTF:96×48×110mm   hole: 92×45;
    XMTD:72×72×110mm   hole: 68×68;  XMTG:48×48×110mm   hole: 45×45;

Setup flow chart
Code Description Setting range Instruction Remarks
SP Setting control point Whole range ºC or 1 defined unit  
AL1 Alarm 1 Whole range ºC or 1 defined unit  
AL2 Alarm 2 Whole range ºC or 1 defined unit  
SC Measurement update -20.0 to 20.0 Measuring value can be modified through
increasing or decreasing this data.
Note: It may be cause inaccurate racy of measuring value when you use this function . Please use the function carefully according to your situation.
0
P Proportional band 0 to 9999 When the P↑,the proportion and differential function↑; if the P↓,the proportion and differential function↓. When P=0,the meter is ON/OFF control 100
I Integration time 0 to 3000s It's mainly used to adjust the static difference. To increase it, the static difference will be reduced, but when it is too high, the static difference will drift instability. 500
d Differential time 0 to 2000s When the I↓,the calculus function↑;
I↑the calculus function↓.
When I=0, no calculus function, it is PD adjustment instrument
100
t Control period 1 to 120s When the d↓,the proportion and calculus function↑; if d↑,the proportion and calculus function↓,but the differential function↑.
When d≤t, it has no differential function
20
Hy Deadband 0.1to 50.0 ON/OFF control only 1.0
At Auto-man 0 to 1
Close auto-man function
Open auto-man function

0
Lock Key lock 0 to 1
All the parameter can rework
Only SP value can rework
>1 All the parameter can not rework
0