XMTF-618T LED digital PID electronic temperature controller with timer
Survey
XMTF-618T LED digital PID electronic temperature controller with timer is double row 3-LED display, respectively display temperature measurement value (PV) and temperature set value (SV) under normal mode;When it is time temperature control, respectively display temperature measurement value (PV) and running time count down (SV),and also provide kinds of time control method selection;The controller can input kinds of signal which are used interchangeably,it adopt ON/OFF(P=0),PID control,allowing an easy parameter setting and convenient inputting,is widely used over temperature automatic control systems of machinery,chemical,ceramics,light industrial,metallurgy,petrifaction and heat treatment and so on.
Main technical Indexes
1, Measurement deviation:±0.5F·S±1,additional cold end compensating deviation±1ºC
2, Input(can be selected):CU50(-50~150),PT100(-80~600),K(-30~999),E(-30~700),
J(-30~900),T(199~400)
3, Relay output (passive) contact capacity: AC250V 5A(resistance load)
period 2~120s can be adjusted.
4, Time range:0~999s or 0~999m(can be selected)
5, Driving solid relay signal output:Driving electric current >15mA no-load voltage>12V,period is about 2S.
6, Work power:AC85V~242V,50HZ Power consumption<3W
7, Work environment:0~50ºC,relative humidity≤85%,without corrode and strong electric radiation.
Meaning of the model code
XMT (1)-6(2) 8 (3)
1: the surface dimension
Blank: 160×80×85 Installation hole 156×76
A: 96×96×80 Installation hole 92×92
D: 72×72×80 Installation hole 68×68
E: 48×96×75 Installation hole 44×92
F: 96×48×75 Installation hole 92×44
G: 48×48×110 Installation hole 44×44
S: 80×160×85 Installation hole 76×156
B:60×120×90 Installation hole 56×116
L:Standard DIN35mm guide way installation
C:80×120×35 wall set installation
Operation display method:'6' 3-key gentle push-switch setting,double row 3-LED digital display,PID control.
2:Additional alarm:
'0' no alarm;
'1' upper limit alarm(upper deviation alarm when it is time temperature control)
Input: '8' input signal can interchange free(no voltage and current input)
3:Suffix Blank:relay output G:solid relay output T:Time control function