• Cj Intellgence Digital Time Temperature Control Instrument (XMTG-7401T)
  • Cj Intellgence Digital Time Temperature Control Instrument (XMTG-7401T)
  • Cj Intellgence Digital Time Temperature Control Instrument (XMTG-7401T)
  • Cj Intellgence Digital Time Temperature Control Instrument (XMTG-7401T)
  • Cj Intellgence Digital Time Temperature Control Instrument (XMTG-7401T)
  • Cj Intellgence Digital Time Temperature Control Instrument (XMTG-7401T)

Cj Intellgence Digital Time Temperature Control Instrument (XMTG-7401T)

Customized: Customized
Certification: RoHS, CE
Brand: Cj
Display Type: LED
Size: 48*48
Transport Package: 1PCS/Box
Customization:

Contact Supplier

Gold Member Since 2006

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XMTG-7401T
Specification
ISO 9001: 2008Others
Trademark
CJ
Origin
China
HS Code
9032900090
Production Capacity
100000PCS/Year

Product Description

Specifications
Temperature controller
Intelligence dual row 4-LED diSplay
Operated with 4-key
Control method: On/off, automatic regulation
Cj Intellgence Digital Time Temperature Control Instrument (XMTG-7401T)
I,Survey:
XMTF/G-7401T intellectual ability temperature regulator series controlled by single chip, free input multi-signals of thermocouple, thermoresistance,movement with hand, ON/OFF control and PID control,besides,it has time function, ,you can adjust time unit hour and minute or minute and second .they are widely used in the automatic control system of the temperature, chemical, ceramics, light, metal, petrochemical and heat treatment industry.
II ,Main technical specification

1.Basic deviation:±0.5%F.S±1  

2.Cold end compensating deviation:≤±2.0ºC

3.Sampling cycle:0.5s

4.Control cycle: relay output 2~120s and can be adjusted

5.Relay output contact capacity: AC220V/5A(resistance load)

6.Driving solid relay signal output:driving electric current≥15mA,voltage≥9V

7.Power: AC85V~242V(switching supply), 50/60Hz,or the other special request.

8.Working condition: temperature 0~50.0ºC, relative humidity≤85% RH, without corrode and strong electric radiation.

9.Size and Installation hole(mm):XMTG:48×48×110     44×44
XMTF:96×48×85      96×44

Parameter code
Series Code Name Setting range Manual Remarks
0 SP Appointed data Determined by P-SL P-SH - 50.0

1
tE
Timing seting

1~59.59
please refer to
Corresponds to "TE" indicator light

10

2
AL1 Temperature
alarm
fixed value alarm : Determined by P-SL,P-SH;
follow-up alarm: 0.0~100.0 .
please refer to
Corresponds to "AL1" indicator light

100

3
P
Proportion
modulus

0.0~200.0
When the P↑,the proportion and differential function↑; If the P↓,the proportion and differential function↓
When P=0,the meter is ON/OFF control.

15.0

4
I Calculus time
0~3000S
It's used to adjust static difference. To increse it ,the static difference will be reduced,but if it is too high, the static difference will drift instability.
240
 
5 d Differential time 0~200S
 
  30
6 At Setting itself
function
OFF:close the function
ON:open the function
Selection of the
Setting itself function
OFF
7 t Control period 2~120 S the movements period ON/OFF of
Setting relays control is no meaning
  20
8 Hy Main control by
drop in level
0.1~100.0 Only have meaning when
main control output is ON/OFF(P=0)
1.0
9 Hy1 Alarm 1
drop in level
0.1~100.0 It has use drop in level setting of alarm
contact output
1.0
10 Pb Sensor error
amendment
±20.0 The sensor have deviation
can use item to revisal
0



11

FILE
 



Filt modulus



0~50
It is the software filter constant of  measurement sampling.The constant ↑,the measurement antijamming capability↑,but the measurement speed  and system response time ↓


20
12 Lock Code lock 0~50 =all the parameter can be revised,or it can't. 0


13
Sn
 


Input type

CU50(),PT100(),K(),E(),J(),T(),S(),
CU50(-50~150.0),
PT100(-199.9~600.0),
K(-30~1300),E(-30~700),
J(-30~900),T(199~400),
S(-30~1600) 

 
14 P_SL Display the high
limit
     P-SL~full range Can set the high limit displaying
input signal
250
15 P_SL Display the low
limit
    Range start ~P-SH Can set the low limit displaying
input signal
0

16
outH Allow output
max value

OUTL~100.0
Can output high amplitude limiting,
manual and ON/OFF output with no effect

100.0

17
outL Allow output
min value

0.0~OUTH
Can output low limit condition,
manual and ON/OFF control output
with no effect

0.0
18 ALP Alarm output
definition
0~1
 
    '0' upper limit alarm
'1' follow-up alarm
0
 
19 tEP Time unit choice 0~1 0:minute and second display 
1:hour and minute display
0
20 COOL System function
choice
ON/ OFF OFF:reverse control(heating control)
ON:positive control(cooling control)
OFF

21
oP_R
Output method
    
-
SSR   solid state relay
RLP  relay output method

RLP

22
oppO Open power output
power

0~100
Soft start function that meters coefficient
after first output of electric power

0

23
CF Fahrenheit and
degree centigrade
selecting

C/F

C:ºC      ;    F:ºF

C
24 dP Display accuracy ON/ OFF   0: have radix point,
1: have no radix point
OFF





25




Int
 





Time function
selection




0~3(Time control side be switched on)
0:common temperature control
1:start timing when it reaches the temperature,and the built-in buzzer will give an alarm output after reaching the time, the controller keep on heating;
2:start timing when it reaches the
temperature,and the built-in buzzer will





0




 

 

 

 
give an alarm output after reaching the
time, the controller stop heating;
3:regular temperature control(no alarm)+time relay function:
start timing when the power is on, alarm relay attracting after reaching the time .

Send your message to this supplier

*From:
*To:
avatar Ms. Vera
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now