Temperature controller
Intelligence dual row 4-LED diSplay
Operated with 4-key
Control method: On/off, automatic regulation
Main technical specification
Measurement deviation: ≤±0.5%F·S±1B
Cold end compensating deviation: ≤±2.0ºC
Sampling cycle: 0.5S
Control cycle: relay output 2~120S , other is 2S.
Relay output contact capacity: AC220V/5A (resistance load) or AC220V/0.3A (perceptual load)
Driving controllable pulse output: ≥3V scope, ≥40us width's over zero or trigger contact pulse
Driving solid relay signal output: driving electric current≥15mA, voltage≥9V.
Continuous PID : 0~10mA (load 500±200Ω), 4~20mA (load 250±100Ω),
or 0~5V (load≥100kΩ) , 1~5V (load≥100kΩ)
Power supply: AC85V~242V, 50/60Hz
Working condition: temperature 0~50.0ºC, relative humidity≤85%RH, without corrode and strong electric radiation.
Product code:
XMT (1) 7 (2) 8 (3)
(1) Meter faceplate and Installation dimension(mm):
Blank: 160×80×80 152×76; A: 96×96×80 92×92;
D: 72×72×100 68×68; E: 48×96×80 44×92;
F: 96×48×85 92×44; S: 80×160×80 76×156;
G: 48×48×110 44×44
(2)Alarm:
"0": no set alarm "1or2": one alarm "5": voice alarm
"3": two group alarm (upper limit, lower limit, positive deviation alarm and negative deviation alarm discretionary setting)
Input signal:"8": Free exchange of the input signal
(3)Control method:
Blank: Relay contact output "A": Single-phase over-zero trigger adjustment
"A3": Three-phase over-zero trigger adjustment "B": Single-phase shift-phase trigger adjustment
"G": Solid state relay output "C": 0-10mA or 4-20mA constant electric current output